Smart Electric SARL

Smart Electric SARLSmart Electric SARLSmart Electric SARL

Smart Electric SARL

Smart Electric SARLSmart Electric SARLSmart Electric SARL
More

Welcome to Smart Electric SARL

Welcome to Smart Electric SARLWelcome to Smart Electric SARLWelcome to Smart Electric SARL

Welcome to Smart Electric SARL

Welcome to Smart Electric SARLWelcome to Smart Electric SARLWelcome to Smart Electric SARL

About Us

Service

Maintenance

Maintenance

 

Our Services

We supply a full range of construction, maintenance, testing and emergency services regarding your High Voltage power systems.

Our procedures are consistent with Utility Pre-Service Inspection and Insurance Company Loss of Use coverage requirements.

Substation Construction

We can advise on the requirements for and the installati

 

Our Services

We supply a full range of construction, maintenance, testing and emergency services regarding your High Voltage power systems.

Our procedures are consistent with Utility Pre-Service Inspection and Insurance Company Loss of Use coverage requirements.

Substation Construction

We can advise on the requirements for and the installation of all  your High Voltage equipment needs. For example, our list of Standard Modular Substation components is as follows:

  1. Steel or aluminum structure, lattice construction or free standing, terminal pole
  2. Incoming phase strain insulators
  3. Main isolating switch. Load break or air break
  4. Aluminum tubular buswork complete with connectors
  5. Bus support insulators and clamps
  6. Surge (lightning) arresters, intermediate class, distribution or station
  7. Power fuses, mounts, holders and refills complete
  8. Flexible cable drops to transformers
  9. Structure and transformer foundations
  10. Transformer, tamper proof or TLO
  11. Switch operating linkage, handle, interlocks, and connectors
  12. Gradient control mat
  13. Equipment grounding conductors/connectors
  14. Fuse caution sign
  15. Fence and grounding cables/connectors
  16. Ground rod, connectors and inspection box
  17. Fence enclosure
  18. Danger signs

Protection, Co-ordination, Short Circuit, Arc Flash

We offer technical services related to the protection and control of your high voltage system up to and including your main low voltage service entrance equipment. This service includes co-ordination studies field testing of many different breakers and relays. Also complete short circuit and arc flash studies. Infrared, Ultra Sonic and Partial Discharge testing.

Underground Cable Installations and Locating

We offer installation of cable ductbanks, cable installation and termination. We also provide field acceptance testing, ie. Hi Pot (High Potential D.C.) testing and Time Domain Reflectometer testing of high voltage cable installations. We offer underground cable location services using the latest available technology.

Co-Generation Projects

We offer supply and installation of Co-Generation projects including viability analysis, material acquisition, installation, operation and continuing maintenance programs.

Maintenance

Maintenance

Maintenance

 

Complete Substation Maintenance Includes…

  • Air Break Switch: Alignment check; contact compression or wipe check; contact cleaning and lubrication;   linkage check and lubrication; minor corrosion touch-up; insulator inspection and cleaning; insulation test;   electrical connections checked for tightness; and mounting bolts checked tight.
  • Lo

 

Complete Substation Maintenance Includes…

  • Air Break Switch: Alignment check; contact compression or wipe check; contact cleaning and lubrication;   linkage check and lubrication; minor corrosion touch-up; insulator inspection and cleaning; insulation test;   electrical connections checked for tightness; and mounting bolts checked tight.
  • Load Interrupter: Includes all Air break Switch items and interrupter inspection; dismantling; continuity check; carbon tracking and accumulation; linkage lubrication; gasket inspection; and internal contact reconditioning.
  • Insulator Inspection, Testing and Cleaning: Check for chipped porcelain; cement deterioration; radial cracks;   glaze deterioration; copper splash or wash damage; clean surface.   Polymer insulators are inspected for surface degradation.
  • Lightning Arrester Inspection and Testing: Inspect for cracks and cement deterioration; clean porcelains; corrosion preventative touch-up; ground conductor inspection; electrical connections tightened.
  • Structure and/or Metal Clad: Check for corrosion and deterioration; touch up paint where necessary.
  • Electrical Connections: Checked for tightness.
  • Fence Bonding: Checked for proper condition and tested with a ground clamp
  • Circuit Breaker Maintenance: Check contact compression; baffle, arc chute, and arc quencher inspection and alignment; blow-out coil assembly inspection; contact cleaning and lubrication; operating mechanism cleaning and lubrication; trip testing; check protective features; cleaning of all parts, contact resistance testing. Relay testing is available upon request
  • Fuse Inspection and Test: Check alignment and adjust; contact cleaning and lubrication; lubrication of dropout mechanism; corrosion preventative touch-up; co-ordination and continuity check; mounting and ground inspection. Fuse link data is recorded.
  • Transformer Maintenance and Test: Bushing cleaning and inspection; radiator inspection; inspect for oil leaks; insulation resistance testing of windings; check all electrical connections; check all indicator gauges; paint touch-up; ratio and phase angle test; check for conductor strain on bushings; oil sample and complete analysis.
  • Primary and Secondary Cable Inspection and Test: All applicable items; check all electrical connections; termination inspection; pot head inspection; megger test insulation; bonding and sheath inspection; DC Hi Pot on request.

Subscribe

Sign up to hear from us about specials, sales, and events.

Contact Us

Drop us a line!

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Better yet, see us in person!

We love our customers, so feel free to visit during normal business hours.

Smart Electric SARL

Lubumbashi, Haut-Katanga, Democratic Republic of the Congo

info@smartelectricsarl.com

Hours

Open today

09:00 – 17:00


Copyright © 2025 Smart Electric SARL - All Rights Reserved.

Powered by GoDaddy

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept